Home › Answers › 2000 W battery

How big a battery to run 2,000 W?

To run 2,000 W for 5 hours you need about 12,346 Wh of LiFePO4: 965 Ah at 12 V, 483 Ah at 24 V or 242 Ah at 48 V. Lead-acid needs 22,222 Wh, because only half of it is usable.

HoursLiFePO4 energy12.8 V25.6 V51.2 VLead-acid
2 h4,938 Wh386 Ah193 Ah97 Ah8,889 Wh · 741 Ah at 12 V
4 h9,877 Wh772 Ah386 Ah193 Ah17,778 Wh · 1482 Ah at 12 V
6 h14,815 Wh1158 Ah579 Ah290 Ah26,667 Wh · 2223 Ah at 12 V
8 h19,753 Wh1544 Ah772 Ah386 Ah35,556 Wh · 2963 Ah at 12 V
10 h24,691 Wh1930 Ah965 Ah483 Ah44,444 Wh · 3704 Ah at 12 V
12 h29,630 Wh2315 Ah1158 Ah579 Ah53,333 Wh · 4445 Ah at 12 V

How it is worked out

  1. The battery feeds the load through an inverter or converter that is about 90 % efficient: 2000 W at the load is 2222.2 W from the battery.
  2. Energy = power × hours, then divided by the share you may use: 90 % of a LiFePO4 bank, 50 % of a lead-acid one (deeper discharge shortens its life sharply).
  3. Amp-hours = watt-hours ÷ the bank's voltage. Round up, and add margin for cold weather and an ageing battery.

Check the 5-hour figure in the runtime calculator · Open it on the benchMy house sizes the whole backup system for 10.0 kWh a day and builds it.

For planning and learning. Use the appliance's nameplate (amps, MCA and MOCP) when you have it, follow your local electrical code, and have a licensed electrician do work on a building's wiring.