Home › Answers › 500 W battery

How big a battery to run 500 W?

To run 500 W for 5 hours you need about 3,086 Wh of LiFePO4: 242 Ah at 12 V, 121 Ah at 24 V or 61 Ah at 48 V. Lead-acid needs 5,556 Wh, because only half of it is usable.

HoursLiFePO4 energy12.8 V25.6 V51.2 VLead-acid
2 h1,235 Wh97 Ah49 Ah25 Ah2,222 Wh · 186 Ah at 12 V
4 h2,469 Wh193 Ah97 Ah49 Ah4,444 Wh · 371 Ah at 12 V
6 h3,704 Wh290 Ah145 Ah73 Ah6,667 Wh · 556 Ah at 12 V
8 h4,938 Wh386 Ah193 Ah97 Ah8,889 Wh · 741 Ah at 12 V
10 h6,173 Wh483 Ah242 Ah121 Ah11,111 Wh · 926 Ah at 12 V
12 h7,407 Wh579 Ah290 Ah145 Ah13,333 Wh · 1112 Ah at 12 V

How it is worked out

  1. The battery feeds the load through an inverter or converter that is about 90 % efficient: 500 W at the load is 555.6 W from the battery.
  2. Energy = power × hours, then divided by the share you may use: 90 % of a LiFePO4 bank, 50 % of a lead-acid one (deeper discharge shortens its life sharply).
  3. Amp-hours = watt-hours ÷ the bank's voltage. Round up, and add margin for cold weather and an ageing battery.

Check the 5-hour figure in the runtime calculator · Open it on the benchMy house sizes the whole backup system for 2.5 kWh a day and builds it.

For planning and learning. Use the appliance's nameplate (amps, MCA and MOCP) when you have it, follow your local electrical code, and have a licensed electrician do work on a building's wiring.