Automatic transfer switch (AC, dual power)
Dual-power automatic transfer switch · 2-pole (L and N) · 63 A · source I and source II, mechanically interlocked: never both · automatic, priority I, back to it after 5 s · accepts 170–260 V

Try it on the benchThe lab drops it on an empty bench and opens its datasheet card.
Typical part: Dual-power automatic transfer switch (2P, DIN rail)
Pins
- I · L (source I)
- I · N (source I)
- II · L (source II)
- II · N (source II)
- OUT · L
- OUT · N
Ratings and limits
| Rating | 63 A, 2 poles (L and N), 230 V AC |
|---|---|
| Sources | I and II, mechanically interlocked |
| Accepts | 170–260 V |
| Transfer | about 30 ms break-before-make; back to priority after an adjustable delay |
How to use it
Moves a house between the grid and an off-grid inverter (or a generator) without ever joining them. With an off-grid inverter as priority, the house runs on solar and battery and falls back to the grid when the inverter stops on low battery. A hybrid inverter already has this switch inside; an external ATS there is only for a generator or a manual bypass.