Home › Solar › Model guides › Luxpower SNA 5000

Luxpower SNA 5000 guide

An all-in-one with two MPPT inputs: solar and the grid can feed the loads together, and the battery backs them up. It talks to most 48 V lithium batteries over the battery cable (BMS communication).

Simulate this kind of system ▸Check my panels for this model

Key ratings

Battery voltage48 V (51.2 V lithium or 48 V lead-acid)
Rated output5,000 W
Surge10,000 VA
Recommended PV power3,200 W + 3,200 W
MPPT inputs2
Max PV open-circuit voltage480 V
MPPT range100–385 V
Max solar input current13 A + 13 A
Max solar charge current100 A
AC charge current60 A

The MPPT range tops out at 385 V, well below the 480 V limit: keep the cold Vmp of each string under 385 V too, or the charger stops tracking on cold bright mornings.

Which system it builds

This unit is the heart of the lab's hybrid solar system: panels, the inverter, a battery and the loads, with the protection in between. In the simulator, set the inverter to 5,000 W and the battery to 48 V in the parts' settings.

Wiring diagram of a hybrid solar system like one built around the Luxpower SNA 5000
The general layout, drawn from the working simulation. The terminal positions on the real unit differ: follow the manual's terminal diagram.

How many panels in series

With a typical 550 W panel (Voc 49.9 V, Vmp 41.9 V, Isc 13.9 A, -0.27 %/°C):

So: 3 to 8 panels per string in a warm climate. With 2 MPPT inputs, 5 per string on each gives 10 panels, 5,500 W against the 6,400 W limit. The panel's 13.9 A short-circuit current is above the 13 A input rating: the charger limits it (a little power is lost at noon); never parallel two strings on that input.

Open the string calculator with the Luxpower SNA 5000 limits filled in →

Battery, fuse and cable

At full output (5,000 W) the inverter draws about 116 A from a 48 V battery. That calls for a fuse or DC breaker of about 150 A and heavy cable, kept short. See the battery bank calculator for the battery size and the inverter size calculator for what the loads need.

Wiring order

  1. Mount the unit on a non-flammable wall with the clearances in the manual, close to the battery (short battery cables).
  2. Battery first, with every breaker open: a 48 V battery, a DC breaker or fuse of about 150 A in the positive cable (full output is about 116 A at 48 V), and the cable size the manual gives for that current. Check polarity twice: reversed battery cables destroy most inverters.
  3. AC output to the house's backup circuits through its own breaker, then the grid input (if you use one) through another. Never connect the AC output to the grid.
  4. Panels last, with the PV isolator open: measure the string's open-circuit voltage with a meter before closing it, and compare it with the limit above.
  5. Power up in order: battery breaker, then the inverter, then the PV isolator, then the grid input. Set the battery type before the first charge.

Settings to check

⚠ This is a design aid to learn from and plan with, not the maker's instructions. Read the manual, follow your local electrical code, and have mains and battery wiring checked by a qualified electrician.

Questions

How many solar panels can I connect to the Luxpower SNA 5000?

With 550 W panels, 3 to 8 in series per string in a warm climate (fewer where it freezes), one string on each of the 2 inputs, up to about 6,400 W in all. Check your own panel's Voc with the string calculator.

What battery does the Luxpower SNA 5000 need?

A 48 V battery. Lithium (LiFePO4) lasts far longer than lead-acid; size it from what you use at night with the battery bank calculator.

Is this an official guide?

No. It is an independent guide by Zen Circuit Lab, worked out from the published specifications (sources below). Ratings can change between hardware versions: the label on your unit and its manual always win.

Sources

Other guides

Growatt SPF 5000 ES · Deye SUN-5K-SG03LP1 · PowMr POW-HVM3.2H-24V-N (3 kW 24 V) · Victron SmartSolar MPPT 100/30 · All model guides